Shelly - DIN rail - "Pro 3EM-3CT63" - Electricity meter - incl. CT - measuring function - WLAN - LAN - BT
- Item no: F23110557
- Weight: 0,06 kg
DIN rail mountable, single or three-phase energy meter
The Shelly Pro 3EM-3CT63 is a DIN rail mountable, single or three phase energy meter. It is supplied with a combined three-phase current transformer (CT), which is mounted directly above a circuit breaker. The Shelly Pro 3EM-3CT63 measures energy consumption accurately and can be used in many applications, such as monitoring industrial machinery, saving energy in homes or offices and managing electrical loads.
*IMPORTANT! This device does not have an integrated relay. A contactor is controlled via a Shelly Pro add-on, which is attached to the Shelly Pro 3EM-3CT63.
- 4-quadrant measurement
- DIN rail mounting
- Various connection types: single or three-phase installations
- Current transformer connection: Non-contact measurements
- Optical pulse display of energy consumption
- Real-time clock: Stored data retains correct time stamps even if the internet connection is interrupted.
- Data logs: Up to 60 days of data are stored on the device and can be retrieved later
- External contactor control: Loads can be controlled based on device automation or scripts. Available with the additional Shelly 3EM Switch add-on
- Photovoltaic compatible
WHY you should choose the shelly pro 3em-3ct63
Professional energy meter
The Shelly Pro 3EM-3CT63 records both the accumulated energy and the instantaneous values of voltage, current, active power and apparent power per phase/channel in real time. It stores the data in non-volatile memory and enables it to be retrieved at one-minute intervals over a period of up to 60 days. It also has a real-time clock that ensures the time is always set correctly - even if the connection to an SNTP server is interrupted.
Functions
LAN, WLAN and Bluetooth connectivity
LAN connection for high security and reliability. Simultaneous use of WLAN and LAN, as a backup if necessary.
4-quadrant measurement
Measurement of capacitive and inductive load types of imported and exported active energy.
Accuracy class B (active energy)
The Shelly Pro 3EM-3CT63 has a measurement accuracy of 1 percent.
Power measurement
Monitors single-phase electrical systems with up to three points simultaneously. Fast notification and at least 60 days storage of 1-minute recordings.
MODBUS support
Enables quick and easy deployment in existing industrial plants.
Script functions
The Shelly Pro 3EM-3CT63 fully supports mJS scripting: so you can create additional features and functionalities.
Technical specifications
Specifications | |
---|---|
Size (H x W x D): | Shelly Pro 3EM-3CT63: 94 x 19 x 69 mm / 3.70 x 0.75 x 2.71 inches |
Shelly 3CT63: | 14 x 54 x 26 mm / 0.55 x 2.12 x 1.02 in |
Weight: | Shelly Pro 3EM-3CT63: 62 g |
Shelly 3CT63: | 32 g |
CT opening: | Ø9 mm / Ø0.35 inch |
Wire diameter: | 6 mm / 10 AWG |
Screw terminals max. torque: | 0.4 Nm / 3.5 lbin |
Cross-section of the conductor: | Shelly Pro 3EM-3CT63: 0.5 to 2.5 mm² / 20 to 14 AWG (solid, stranded and ferrules) |
Shelly 3CT63: | 0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded and ferrules) |
Stripping length of the conductor: | 6 to 7 mm / 0.24 to 0.28 in |
Assembly: | Shelly Pro 3EM-3CT63: DIN rail |
Shelly 3CT63: | Freestanding on phase cable |
Housing material: | Plastic |
Color of the housing: | White |
Environmental | |
Ambient temperature: | -20 °C to 40 °C |
Humidity: | 30 % to 70 % relative humidity |
Max. Altitude above sea level: | 2000 m |
Electrical | |
Power supply: | 100 - 260 V~ 50/60 Hz |
Power consumption of the device: | < 3 W |
Shelly 3CT63 electrical strength: | 1000 V~, 60 sec Sensors, measuring devices |
Internal temperature sensor: | Yes |
Voltmeter (RMS for each phase): | 100 - 260 V |
Voltmeter accuracy: | ±1 % |
Ammeters (RMS via current transformers for each phase and neutral conductor): | 0 - 63 A |
Compatible CT: | 3CT63 |
Accuracy of the ammeter: | ±1 % (2 - 63 A) ±2 % (1 - 2 A) ±5 % (0 - 1 A) |
Power and energy meters: | Active and apparent power Active and apparent energy Power factor Fundamental active and reactive energy |
Channel-to-channel calibration Minimum load: | 500 W per channel |
Threshold value for no load: | 30 VA per channel |
Storage of measurement data: | At least 60 days with a data resolution of 1 minute |
Data export: | CSV for PQ-recorded values |
Export in JSON format via RPC | |
Radio | |
WLAN | |
HF band: | 2400 - 2495 MHz |
Max. RF power: | < 20 dBm |
Protocol: | 802.11 b/g/n |
Range: | Up to 50 m outdoors, up to 30 m indoors (depending on local conditions) |
Bluetooth | |
Protocol: | 4.2 |
Frequency band: | 2400-2483.5 MHz |
Max. RF power: | <4 dBm |
Range: | Up to 30 m outdoors, up to 10 m indoors (depending on local conditions) |
Microcontroller unit | |
CPU: | ESP32-D0WDQ6 |
Flash: | 8 MB |
Firmware functions | |
WebHooks (URL actions): | 20 with five URLs per hook |
WLAN range extender: | Yes |
BLE gateway | Yes |
Scripting: | Yes |
MQTT: | Yes |
Encryption: | Yes |